DTC Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E9. Refer to Ground Inspection in Refer to Circuit Inspection .
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair or replace ground connection.
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
- Clear the mixture ratio self-learning value. Refer to Work Procedure .
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171 detected? Is it difficult to start engine?
YES>>
Perform trouble diagnosis for DTC P0171. Refer to DTC Description .
NO>>
GO TO 3.
- CHECK HO2S2 GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal 1 F55 2 F14 98 Existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Bank Connector Terminal Connector Terminal 1 F55 1 F14 90 Existed - Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.
HO2S2 - Continuity Bank Connector Terminal 1 F55 1 Ground Not existed ECM - Continuity Bank Connector Terminal 1 F14 90 Ground Not existed - Also check harness for short to power.
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
Repair open circuit, short to ground or short to power in harness or connectors.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Refer to Component Inspection . Is the inspection result normal?
YES>>
INSPECTION END
NO>>
Replace malfunctioning heated oxygen sensor 2. Refer to Exploded View .