LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Nissan-Datsun >> 2023 >> Maxima SR >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System (DTC/Circuit Diagnosis) >> Circuit Diagnosis >> Encoder >> Driver Side >> Diagnosis Procedure
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Diagnosis Procedure

  1. CHECK ENCODER SIGNAL 
      1. Ignition switch ON.
      2. Check signal between main power window and door lock/unlock switch harness connector and ground with oscilloscope.
        Signal name (+) (-) Signal (Reference value)
        Main power window and door lock/unlock switch
        Connector Terminal
        Encoder signal 1 D7 5 Ground Refer to following signals
        Encoder signal 2 4
        GNSDB50847Courtesy of NISSAN

    Is the inspection result normal?

    YES>>

    Replace main power window and door lock/unlock switch. Refer to Removal and Installation .

    NO>>

    GO TO 2.

  2. CHECK ENCODER SIGNAL CIRCUIT 
      1. Ignition switch OFF.
      2. Disconnect main power window and door lock/unlock switch connector and front power window motor LH connector.
      3. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
        Main power window and door lock/unlock switch Front power window motor LH Continuity
        Connector Terminal Connector Terminal
        D7 4 D9 5 Yes
        5 3
      4. Check continuity between main power window and door lock/unlock switch harness connector and ground.
        Main power window and door lock/unlock switch Ground Continuity
        Connector Terminal
        D7 4 No
        5

    Is the inspection result normal?

    YES>>

    GO TO 3.

    NO>>

    Repair or replace harness.

  3. CHECK ENCODER POWER SUPPLY 
      1. Connect main power window and door lock/unlock switch connector.
      2. Ignition switch ON.
      3. Check voltage between front power window motor LH harness connector and ground.
        (+) (-) Voltage (Approx.)
        Front power window motor LH
        Connector Terminal
        D9 4 Ground Battery voltage

    Is the inspection result normal?

    YES>>

    GO TO 5.

    NO>>

    GO TO 4.

  4. CHECK ENCODER POWER SUPPLY CIRCUIT 
      1. Ignition switch OFF.
      2. Disconnect main power window and door lock/unlock switch connector.
      3. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
        Main power window and door lock/unlock switch Front power window motor LH Continuity
        Connector Terminal Connector Terminal
        D7 14 D9 4 Yes
      4. Check continuity between main power window and door lock/unlock switch harness connector and ground.
        Main power window and door lock/unlock switch Ground Continuity
        Connector Terminal
        D7 14 No

    Is the inspection result normal?

    YES>>

    Replace main power window and door lock/unlock switch. Refer to Removal and Installation .

    NO>>

    Repair or replace harness.

  5. CHECK GROUND CIRCUIT 1 
      1. Ignition switch OFF.
      2. Check continuity between front power window motor LH harness connector and ground.
        Front power window motor LH Ground Continuity
        Connector Terminal
        D9 6 Yes

    Is the inspection result normal?

    YES>>

    Replace front power window motor LH. Refer to Removal and Installation .

    NO>>

    GO TO 6.

  6. CHECK GROUND CIRCUIT 2 
      1. Disconnect main power window and door lock/unlock switch connector.
      2. Check continuity between main power window and door lock/unlock switch harness connector and front power window motor LH harness connector.
        Main power window and door lock/unlock switch Front power window motor LH Continuity
        Connector Terminal Connector Terminal
        D7 12 D9 6 Yes
      3. Check continuity between main power window and door lock/unlock switch harness connector and ground.
        Main power window and door lock/unlock switch Ground Continuity
        Connector Terminal
        D7 12 No

    Is the inspection result normal?

    YES>>

    Replace main power window and door lock/unlock switch. Refer to Removal and Installation .

    NO>>

    Repair or replace harness.