Diagnosis Procedure
- CHECK POWER WINDOW SWITCH OUTPUT SIGNAL
- Turn ignition switch ON.
- Check signal between power window main switch harness connector and ground using an oscilloscope.
(+) (-) Signal
(Reference value)Power window main switch Connector Terminal D5 14 Ground
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
GO TO STEP 2 .
- CHECK POWER WINDOW SERIAL LINK SIGNAL
- Turn ignition switch OFF.
- Disconnect power window main switch connector.
- Turn ignition switch ON.
- Check voltage between power window main switch harness connector and ground.
(+) (-) Voltage (V) Power window main switch Connector Terminal D5 14 Ground 9 - 16
Is the inspection result normal?
YES
Replace power window main switch. Refer to REMOVAL AND INSTALLATION .
NO
GO TO STEP 3 .
- CHECK POWER WINDOW SERIAL LINK CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector.
- Check continuity between BCM harness connector and power window main switch harness connector.
BCM Power window main switch Continuity Connector Terminal Connector Terminal M121 8 D5 14 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M121 8 Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.