Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CONNECTOR INSPECTION
- Turn ignition switch OFF.
- Disconnect ABS actuator and electric unit (control unit) connectors.
- Check connectors and terminals for deformation, disconnection, looseness or damage.
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace as necessary.
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) IGNITION POWER SUPPLY CIRCUIT
Check voltage between ABS actuator and electric unit (control unit) connector E33 terminal 6 and ground.
ABS actuator and electric unit (control unit) Ground Condition Voltage Connector Terminal E33 6 - Ignition switch ON Battery voltage Ignition switch OFF 0V Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair or replace malfunctioning components.
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between ABS actuator and electric unit (control unit) connector E33 terminals 13, 38 and ground.
ABS actuator and electric unit (control unit) - Continuity Connector Terminal E33 13 Ground Yes 38
Is the inspection result normal?
YES
Replace ABS actuator and electric unit (control unit). Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace malfunctioning components.