Work Support
| Support Item | Setting | Description | |
|---|---|---|---|
| SHORT CRANKING OUTPUT | Start | 70 msec | Starter motor operation duration times. |
| 100 msec | |||
| 200 msec | |||
| End | - | ||
| INSIDE ANT DIAGNOSIS | - | This function allows inside key antenna self-diagnosis. | |
| LOCK/UNLOCK BY I-KEY | On * | Door lock/unlock by I-Key ON. | |
| Off | Door lock/unlock by I-Key OFF. | ||
| AUTO LOCK SET | Mode 1 | OFF | Auto door lock operation time can be changed in this mode. |
| Mode 2 | 30 sec. | ||
| Mode 3 * | 1 min. | ||
| Mode 4 | 2 min. | ||
| Mode 5 | 3 min. | ||
| Mode 6 | 4 min. | ||
| Mode 7 | 5 min. | ||
| IGN/ACC BATTERY SAVER | On * | Battery saver system ON. | |
| Off | Battery saver system OFF. | ||