Diagnosis Procedure
- INSPECTION START
Confirm the detected malfunction (A or B). Refer to "DTC LOGIC ".
Which malfunction is detected?
A >> GO TO 2.
B >> GO TO 9.
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E38. Refer to
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES >> GO TO 3.
NO >> Repair or replace ground connection.
- CHECK HO2S2 CONNECTOR FOR WATER
- Disconnect heated oxygen sensor 2 harness connector.
- Check connectors for water.
Water should not exist.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace harness or connectors.
- CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Connector Terminal Connector Terminal F49 1 F8 59 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Connector Terminal Connector Terminal F49 4 F8 50 Existed - Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.
HO2S2 Ground Continuity Connector Terminal F49 4 Ground Not existed ECM Ground Continuity Connector Terminal F8 50 Ground Not existed - Also check harness for short to power.
Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES >> GO TO 8.
NO >> GO TO 7.
- REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2. Refer to "EXPLODED VIEW ".
CAUTION:- Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J43897-12)] and approved Anti-seize Lubricant (commercial service tool).
>> INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
>> INSPECTION END
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E38. Refer to
"CIRCUIT INSPECTION
".
Is the inspection result normal?
YES >> GO TO 10.
NO >> Repair or replace ground connection.
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
- Clear the mixture ratio self-learning value. Refer to "MIXTURE RATIO SELF-LEARNING VALUE CLEAR: SPECIAL REPAIR REQUIREMENT ".
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 detected? Is it difficult to start engine?
YES >> Perform trouble diagnosis for DTC P0172. Refer to "DTC LOGIC ".
NO >> GO TO 11.
- CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor 2 harness connector.
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Connector Terminal Connector Terminal F49 1 F8 59 Existed - Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 12.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Check the continuity between HO2S2 harness connector and ECM harness connector.
HO2S2 ECM Continuity Connector Terminal Connector Terminal F49 4 F8 50 Existed - Check the continuity between HO2S2 harness connector or ECM harness connector and ground.
HO2S2 Ground Continuity Connector Terminal F49 4 Ground Not existed ECM Ground Continuity Connector Terminal F8 50 Ground Not existed - Also check harness for short to power.
Is the inspection result normal?
YES >> GO TO 13.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
- CHECK HEATED OXYGEN SENSOR 2
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES >> GO TO 15.
NO >> GO TO 14.
- REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2. Refer to "EXPLODED VIEW ".
CAUTION:- Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J43897-12)] and approved Anti-seize Lubricant (commercial service tool).
>> INSPECTION END
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
>> INSPECTION END