Inspection Procedure
- SELF-DIAGNOSIS RESULT CHECK
Check self-diagnosis results.
SELF-DIAGNOSIS RESULTSSelf-diagnosis results STOP LAMP SW Is the above displayed in the self-diagnosis display items?
YES: GO TO 2.
NO: Inspection End.
- CONNECTOR INSPECTION
- Disconnect the ABS actuator and electric unit (control unit) and stop lamp switch connectors.
- Check the terminals for deformation, disconnection, looseness or damage.
OK or NG
OK: GO TO 3.
NG: Repair or replace as necessary.
- CHECK STOP LAMP SWITCH CIRCUIT
- Connect stop lamp switch connector.
- Check voltage between ABS actuator and electric unit (control unit) connector E33 terminal 20 and ground.VOLTAGE AND CONTINUITY SPECIFICATIONS
ABS actuator and electric unit (control unit) Ground Condition Voltage (Approx.) Connector Terminal E33 20 - Brake pedal depressed Battery voltage Brake pedal released 0V Is the inspection result normal?
YES: Replace ABS actuator and electric unit (control unit). Refer to "REMOVAL AND INSTALLATION ".
NO: GO TO 4
- CHECK STOP LAMP SWITCH CIRCUIT FOR OPEN
- Disconnect stop lamp switch connector.
- Check continuity between ABS actuator and electric unit (control unit) connector E33 (A) terminal 20 and stop lamp switch connector E60 (B) terminal 2 (with CVT), or E60 (C) terminal 2 (with M/T).VOLTAGE AND CONTINUITY SPECIFICATIONS
ABS actuator and electric unit (control unit) stop lamp switch Continuity Connector Terminal Connector Terminal E33 (A) 20 E60 (B) (with CVT) 2 Yes E60 (C) (with M/T) Is the inspection result normal?
YES: GO TO 5.
NO: Repair or replace as necessary.
- CHECK STOP LAMP SWITCH CIRCUIT FOR SHORT
Check continuity between ABS actuator and electric unit (control unit) connector E33 terminal 20 and ground.
VOLTAGE AND CONTINUITY SPECIFICATIONSABS actuator and electric unit (control unit) Ground Continuity Connector Terminal E33 20 - No Is the inspection result normal?
YES: Replace stop lamp switch.
NO: Repair harness or connectors.