Component Inspection
- CHECK HEATED OXYGEN SENSOR 3 HEATER
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor 3 harness connector.
- Check resistance between HO2S3 terminals as follows.TERMINALS RESISTANCE REFERENCE
Terminal Resistance 2 and 3 3.4 - 4.4 Ω [at 25°C (77°F)] 1 and 2, 3, 4 ∞ Ω (Continuity should not exist) 4 and 1, 2, 3
Is the inspection result normal?
YES: INSPECTION END
NO: GO TO 2.
- REPLACE HEATED OXYGEN SENSOR 3
Replace heated oxygen sensor 3.
CAUTION:- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
INSPECTION END