Inspection Procedure
- CHECK CONNECTOR
- Turn ignition switch "OFF".
- Disconnect the stop lamp switch connector E116 and ABS actuator and electric unit (control unit) connector E24 and check terminals for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or replace terminal.
- Reconnect connectors securely.
- Start engine.
- Repeat pumping brake pedal carefully several times, then perform the self-diagnosis.
Do any self-diagnosis items appear?
OK: GO TO 2.
NG: Poor connection. Repair or replace applicable connector.
- CHECK STOP LAMP SWITCH CIRCUIT
- Turn ignition switch "OFF".
- Disconnect stop lamp switch connector E116 and ABS actuator and electric unit (control unit) connector E24.
- Check continuity between stop lamp switch harness connector E116 and ABS actuator and electric unit (control unit) harness connector E24.
41 - 2 : Continuity should exist.
OK or NG
OK: Connect connectors and perform an ABS actuator and electric unit (control unit) self-diagnosis.
NG: Open or short in harness. Repair or replace harness.