Terminal No. Wire color Item Ignition switch Condition Voltage (V) (Approx.)
1 B Ground - - 0V
2 Y Sensor power ON - 5V
3 W/G Air mix door motor (front) CW ON Clockwise rotation Battery voltage
4 G Air mix door motor (front) CCW ON Counterclockwise rotation Battery voltage
5 BR/W Mode door motor CW ON Clockwise rotation Battery voltage
6 P/L Mode door motor CCW ON Counterclockwise rotation Battery voltage
7 O Intake door motor CCW ON Counterclockwise rotation Battery voltage
8 G/B Intake door motor CW ON Clockwise rotation Battery voltage
9 L/B Intake sensor ON - 0 -- 5V
11 Y/B Rear defroster request ON - Battery voltage
12 W/R Compressor ON signal ON A/C switch OFF 5V
ON A/C switch ON 0V
14 Y/G Power supply for IGN ON - Battery voltage
15 P Sensor ground ON - 0V
16 GR Mode door motor feedback ON - 0 -- 5V
18 SB Air mix door motor (front) feedback ON - 0 -- 5V
19 LG Defroster door motor CW ON Clockwise rotation Battery voltage
20 P/B Defroster door motor CCW ON Counterclockwise rotation Battery voltage
21 V/R Sensor return ON - 0 -- 5V
22 Y/R Power supply for BAT - - Battery voltage
23 R/L Illumination + ON Park lamps ON Battery voltage
24 BR Illumination - - Park lamps ON
G04756301
25 LG/B Defroster door motor feedback ON - 0 -- 5V
26 R/B Front blower request ON Front blower motor OFF Battery voltage
Front blower motor ON 0V
29 Y/L Water valve ON Water valve open 0V
Water valve closed 5V
30 W/G Water valve ON Water valve open 0V
Water valve closed Battery voltage
34 L CAN-H ON - 0 -- 5V
35 P CAN-L ON - 0 -- 5V
36 L/R Fan ON signal ON Blower control dial OFF 5V
Blower control dial ON 0V
40 G/R Variable Blower Control output ON - 0 -- 5V