July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!
Main Relay (Computer/Fuel System): Testing and Inspection
Component Inspection
ECM RELAY 1.Apply 12V direct current between ECM relay terminals 1 and 2. 2.Check continuity between ECM relay terminals 3 and 5, 6 and 7. 3.If NG, replace ECM relay.