LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2017 >> Outlander ES, AWD >> Repair and Diagnosis >> Brakes >> Traction Control >> Active Stability Control System (ASC) - With Diagnostics >> On-Vehicle Service >> Brake Fluid Pressure Sensor Calibration
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Brake Fluid Pressure Sensor Calibration

CAUTION: Before performing calibration, check that the brake fluid pressure sensor-related diagnostic trouble code is not stored.
CAUTION: After the next operation has been completed, carry out the calibration to make ASC-ECU learn the neutral position of the brake fluid pressure sensor.
CAUTION: Always perform the calibration with the brake pedal released (stoplight switch is turned off).
  1. Park the vehicle on a level surface.
    CAUTION: Before connecting or disconnecting scan tool (M.U.T.-III), always turn the ignition switch to the LOCK (OFF) position.
  2. Before setting scan tool (M.U.T.-III), turn the ignition key to the LOCK (OFF) position.
  3. Turn the ignition switch to the ON position.
  4. Select "ABS/ASC/ASTC/WSS."
  5. Select "Special function."
  6. Select "Sensor calibration."
  7. Select "M/C pressure calibration."
  8. Before removing scan tool (M.U.T.-III) from the vehicle, turn the ignition key to the LOCK (OFF) position.