Service Specifications
Item
Standard value
Limit
Generator output line voltage drop (at 30 A) V
-
Maximum 0.3
Output current
-
70 % of normal output current
Regulated voltage ambient temperature at voltage regulator V
-30°C (-22°F)
14.25 - 14.95
-
20°C (68°F)
13.85 - 14.35
-
100°C (212°F)
13.71 - 12.89
-