SERVICE SPECIFICATION

ITEM STANDARD VALUE LIMIT
Fan control module Condenser fan motor connector voltage V
  • When the A/C switch is off
  • Measure the fan control module-side connector
1 or less -
  • When the A/C switch is "ON" position
  • Measure the fan control module-side connector
Repeat 8.2 +/- 2.6 and Battery positive voltage +/- 2.6 -
Fan control module connector voltage V
  • When the ignition switch is "ON" position
  • Measure the harness-side connector
Battery positive voltage -
High-pressure valve opening pressure of radiator cap kPa (psi) 93 - 123 (14 - 18) Minimum 83 (12)
Thermostat Valve opening temperature of thermostat °C (°F) 82 +/- 1.5 (180 +/- 3) -
Full-opening temperature of thermostat °C (°F) 95 (203) -
Valve lift mm (in) 2.4L Engine 8.5 (0.33) or more -
3.8L Engine 9.0 (0.35) or more -