LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2006 >> Lancer Evolution MR >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System - Lancer Evolution >> Charging System Diagnosis >> Troubleshooting Guide
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Troubleshooting Guide

The charging system troubleshooting guide is shown in the following steps.

  1. STEP 1. 

    Q: Is the battery in good condition? (Refer to  BATTERY CHECK  .) 

    YES:  Go to Step 2.

    NO:  Charge or replace the battery.

  2. STEP 2. 

    Q: Is the generator drive belt in good condition? (Refer to  DRIVE BELT (FOR GENERATOR, WATER PUMP AND POWER STEERING OIL PUMP) (CHECK CONDITION)  .) 

    YES:  Go to Step 3.

    NO:  Adjust the belt tension or replace the belt.

  3. STEP 3. 

    Does the generator malfunction light turn on brightly when the ignition switch is turned to the "ON" position? 

    YES:  Go to Step 4.

    NO: 

    • Check the ignition switch. (Refer to INSPECTION .)
    • Check for burnt-out generator malfunction light bulb.
    • Check the generator. (Refer to INSPECTION  .)
    • Check the generator malfunction light-related circuits.
  4. STEP 4. 

    Q: Does the generator malfunction light go out after starting the engine? 

    YES:  Go to Step 5.

    NO:  Check the generator (Refer to INSPECTION  .)

  5. STEP 5. 

    Q: Is an oscilloscope available? 

    YES:  Go to Step 6.

    NO:  Go to  Step 7.

  6. STEP 6. 

    Q: Does the oscilloscope show a normal wave pattern? (Refer to  WAVE PATTERN CHECK USING AN OSCILLOSCOPE   .) 

    YES:  Go to Step 7.

    NO:  Check the generator. (Refer to INSPECTION  .)

  7. STEP 7. 
    • Engine: 2,500 r/min
    • Headlight: ON (high beam)
    • Voltage between generator "B" terminal and the positive battery terminal

      OK: 0.5 V or less

    • Voltage between the negative battery terminal and generator body

      OK: 0.5 V or less

    Q: Are the generator output line and ground line in good condition? 

    YES:  Go to Step 8.

    NO: 

    • Check the generator output line.
    • Check the generator ground line.
  8. STEP 8. 

    Q: Is the output current normal? (Refer to  OUTPUT CURRENT TEST   .) 

    YES:  Go to Step 9.

    NO:  Check the generator (Refer to INSPECTION  .)

  9. STEP 9. 

    Q: Is the regulated voltage normal? (Refer to Refer to  REGULATED VOLTAGE TEST   .) 

    YES:  Go to Step 10.

    NO:  Check the generator (Refer to INSPECTION  .)

  10. STEP 10. 

    Q: Are the voltage drops in the generator output line normal? (Refer to  GENERATOR OUTPUT LINE VOLTAGE DROP TEST   .) 

    YES:  Generator is normal. Check other systems.

    NO:  Check the output line.