LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2003 >> Lancer Evolution >> Repair and Diagnosis (Single Page) >> Quick Lookups >> Common Specs & Procedures >> Charging System >> Generator >> Service Specifications
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Service Specifications

GENERATOR SPECIFICATIONS

Application Specification
Type (1)
Rated Output 85 Amps
Regulated Voltage (Ambient Temperature At Voltage Regulator) - °F (°C)
-4 (-20) 14.2-15.4
68 (20) 13.9-14.9
140 (60) 13.4-14.5
176 (80) 13.1-14.5
Maximum Generator Output Line Voltage Drop At 30 Amps .3 Volt
Output Current 70 % Of Normal Output Current
Field Coil Resistance About 2-5 Ohms
Minimum Brush Protrusion Length .08" (2.0 mm)
Voltage Regulator Type (2)
(1) Battery voltage sensing.
(2) Electronic built-in type.