O2 Sensor Failure Symptom(s)
- If the upstream sensor fails it may result in poor performance and rough idle.
- Poor emissions control will cause the MIL to illuminate.
- As soon as the EMS2000 has detected an upstream oxygen sensor failure, it will default the fuel control to open loop operation.
- Slow response of sensor due to ageing or possible contaminated sensor tip.