Door Glass Longitudinal Adjustment
- Make sure full length of door glass is seated under lip of weatherstrip when door glass is fully raised. See Figure
.
- Remove lower door trim panel and watershields. See DOOR TRIM PANEL
under REMOVAL & INSTALLATION.
- Working through openings in door, loosen two regulator-to-glass bolts. See Figure
.
- Align door glass so it contacts weatherstrip evenly front-to-back and is fully seated in weatherstrip.
- Tighten regulator-to-glass bolts to 45-61 INCH Lbs (5-7 N. m)
- Lower and raise door glass several times to make sure alignment is correct.
- Install watershields and lower door trim panel. See DOOR TRIM PANEL