Remove/Install Diaphragm Capsule For WASTEGATE - Ar09.40-D-1002-04TSR
| Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | AS00.00-Z-0002-01A |
Engine 651 in model 907
MODIFICATION NOTES
| 02.10.2019 | Operation step "Attach/remove hand vacuum pump," added | Operation steps 10, 16 |
| 02.10.2019 | Repair materials address changed to BR00.45-Z-1027-07A | Operation step 17 |
| Number | Designation | Engine 651 in model 907 | |
|---|---|---|---|
| BA09.40-N-1010-02TSR | Nut, diaphragm capsule to diaphragm capsule holder | Nm | 9 |
REPAIR MATERIALS
| Number | Designation | Order number |
|---|---|---|
| BR00.45-Z-1027-07A | "Yellow" locking paint | Lackfabrik Bader GmbH & Co. KG Dieselstrasse 34 73734 Esslingen Germany Tel.: +49 711 381607 Fax. +49 711 383092 |
Remove
- Remove vacuum hose (1) from wastegate aneroid capsule (2).
- Remove safety clips from the nuts (4, 5).
- Loosen nut (5).
- Remove nut (4) from the control rod (3).
- Remove nuts (6) from the wastegate diaphragm capsule (2).
- Remove wastegate aneroid capsule (2).
Install
- Bring wastegate aneroid capsule (2) into the installation position.
To do this, guide the control rod (3) through the hole in the mounting bolt of the lever (7).
- Attach wastegate diaphragm capsule (2) with nuts (6) to the bracket D
.
Adjust
- Turn nut (5) in the direction of the wastegate diaphragm capsule (2).
In order to achieve the necessary clearance of the control rod (3).
Attach hand vacuum pump to the wastegate diaphragm capsule (2).
- Actuate wastegate diaphragm capsule (2) with
manual vacuum pump until control rod (3) is at end stop.
If a new wastegate diaphragm capsule (2) was installed,
↓
actuate it multiple times with a vacuum of at least 700 mbar.
- Press lever (7) to end stop in direction of wastegate diaphragm capsule (2) and hold.
- Attach nut (4) to the lever (7) with zero clearance up to end stop.
- Mark nut (4) and turn by exactly 3.5 revolutions on the thread in the direction of the lever (7).
The necessary preload is achieved as a result.
- Secure control rod (3) with the nut (5) against the lever (7) and tighten the nut (5).
While doing so, counterhold the nut (4).
Remove hand vacuum pump of the wastegate diaphragm capsule (2).
- Secure nuts (4, 5, 6) using temperature-resistant locking paint.
- Attach safety clips of the nuts (4, 5).
- Install vacuum hose (1) at boost pressure control flap diaphragm capsule (2).