Remove/Install Aneroid Capsule For Boost Pressure Control Flap - Ar09.40-D-1002-01TSR
| Risk of injury . Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | AS00.00-Z-0002-01A |
Engine 651 in model 907
MODIFICATION NOTES
| 02.10.2019 | Operation step "Attach/remove hand vacuum pump," added | Operation steps 10, 16 |
| 02.10.2019 | Repair materials address changed to BR00.45-Z-1027-07A | Operation step 17 |
| Number | Designation | Engine 651 in model 907 | |
|---|---|---|---|
| BA09.40-N-1010-02TSR | Nut, diaphragm capsule to diaphragm capsule holder | Nm | 9 |
REPAIR MATERIALS
| Number | Designation | Order number |
|---|---|---|
| BR00.45-Z-1027-07A | "Yellow" locking paint | Lackfabrik Bader GmbH & Co. KG Dieselstrasse 34 73734 Esslingen Germany Tel.: +49 711 381607 Fax. +49 711 383092 |
Remove
- Remove vacuum hose (1) from boost pressure control flap aneroid capsule (2).
- Remove safety clips from the nuts (4, 5).
- Loosen nut (5).
- Remove nut (4) from the control rod (3).
- Remove nuts (6) from the boost pressure control flap diaphragm capsule (2).
- Remove boost pressure control flap aneroid capsule (2).
Install
- Bring boost pressure control flap aneroid capsule (2) into the installation position.
To do this, guide the control rod (3) through the hole in the mounting bolt of the lever (7).
- Attach boost pressure control flap diaphragm capsule (2) with nuts (6) to the bracket
.
Adjust
- Turn nut (5) in the direction of the diaphragm capsule boost pressure control flap (2).
in order to achieve the necessary clearance of the control rod (3).
Attach hand vacuum pump to the boost pressure control flap diaphragm capsule (2).
- Actuate boost pressure control flap diaphragm capsule (2) with
manual vacuum pump until control rod (3) is at end stop.
If a new boost pressure control flap diaphragm capsule (2) was installed,
↓
actuate it multiple times with a vacuum of at least 700 mbar.
- Press lever (7) to end stop in direction of boost pressure control flap diaphragm capsule (2) and hold.
- Attach nut (4) to the lever (7) with zero clearance up to end stop.
- Mark nut (4) and turn by exactly 3.5 revolutions on the thread in the direction of the lever (7).
The necessary preload is achieved as a result.
- Secure control rod (3) with the nut (5) against the lever (7) and tighten the nut (5).
While doing so, counterhold the nut (4).
Remove hand vacuum pump from the boost pressure control flap diaphragm capsule (2).
- Secure nuts (4, 5, 6) with temperature resistant locking paint.
- Install safety clips of the nuts (4, 5).
- Install vacuum hose (1) at boost pressure control flap diaphragm capsule (2).