LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2019 >> Sprinter 3500XD Van Cargo, RWD >> Repair and Diagnosis >> Engine Performance >> System >> Mixture Formation - Description & Operation, General Information, Basic Knowledge, Safety Precautions >> Basic Knowledge >> Thermal Management, Function - GF07.10-D-1012TSA
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Thermal Management, Function - GF07.10-D-1012TSA

Engine 651 in model 907 

Block diagram 

G13786497

Function requirements for thermal management, general points 

Thermal management, general 

The coolant temperature, the exhaust gas temperature, and the fuel pressure of the engine are regulated with the heat management controlled by the CDI control unit. The following advantages arise from this:

Thermal management controlling is dependent on the following sensors and signals:

Function sequence for thermal management 

The thermal management is described in the following points:

Function sequence for coolant thermostat 

The two-disk thermostat can take the following positions:

The following advantages result from regulating the refrigerant temperature of the engine:

Schematic diagram 

G13786498

Function sequence for maximum heating combustion 

With the maximum heating combustion more heat is introduced into the refrigerant by a new combustion strategy on the engine side.

The following function conditions must be met simultaneously:

During maximum heating combustion, a higher exhaust gas temperature is achieved by means of 2 preinjections from the fuel injectors with a significantly higher fuel quantity and a retarded main injection. This process, in combination with exhaust gas recirculation (EGR), causes more heat to be transferred to the coolant inside the engine, allowing for more rapid attainment of the optimum operating temperature and improved warming of the vehicle interior. For this purpose, exhaust gas recirculation positioner is actuated by the CDI control unit.

IMPORTANT The CDI control unit regulates, stabilizes and increases the idle speed depending on operating conditions and engine loads if the accelerator pedal is not actuated.

Function sequence for fuel preheating system 

Fuel preheating is achieved using the following regulation strategies:

Pressure regulating valve regulation 

The fuel pressure is regulated by the pressure regulating valve during the starting procedure and for fuel heating. The quantity control valve is opened in a controlled manner.

Pressure regulating valve regulation takes place under one of the following conditions:

Pressure regulating valve regulation causes the cold fuel to be heated rapidly by the fuel being forced at high pressure through a narrow gap in the pressure regulating valve.

2-control concept regulation 

The fuel pressure is jointly regulated in idle and in deceleration mode by the pressure regulating valve and quantity control valve.

Quantity control valve regulation 

The fuel pressure is regulated through the quantity control valve as from 30 seconds after engine start and as from a fuel temperature of 20 °C.

IMPORTANT With the 2-regulator design and with regulation by the quantity control valve, the fuel is heated less than is the case with pressure regulating valve regulation.

Function sequence for fuel tank protection 

Increasing the fuel pressure through the high-pressure pump from 4.5 bar to 1800 bar increases the fuel's temperature.

To protect the fuel tank from overheating, the CDI control unit reads in values from the fuel temperature sensor and thus monitors the temperature of the fuel delivered to the high-pressure pump. If the temperature of the fuel routed to the high-pressure pump increases to over 90 °C, the CDI control unit reduces the injection quantity and the fuel pressure using the pressure regulating valve

This causes less fuel to be compressed.

The CDI control unit causes the excess fuel to return to the fuel tank via the quantity control valve.

If the temperature of the fuel routed to the high-pressure pump drops below 90 °C, the protection function is deactivated by the CDI control unit.

Function sequence for fan control 

The CDI control unit actuates the fan. Thus, the fan speed is prescribed continuously by the CDI control unit.

Delayed fan switch off 

At "ignition OFF" the fan motor runs on for 5 minutes, when the coolant temperature, CDI control unit temperature or a thermal input integral calculated based on engine load, coolant temperature, vehicle speed and outside temperature (averaged over the last 6 minutes) exceeds specified threshold values.

If the battery voltage drops down a lot, the delayed fan switch off is suppressed.

IMPORTANT The delayed fan switch off is not broken off by "ignition ON". When starting the engine in delayed fan switch off the fan regulation for normal operation is suppressed until the delayed fan switch off is completed.

Function sequence for overheating protection 

The overheating protection protects against engine damage if there is a thermal overload. At a coolant temperature above 106 °C, the injection quantity is reduced based on the characteristics maps stored in the CDI control unit. Reduction occurs depending on the coolant temperature and oil temperature. To do this, the CDI control unit reads in the signals of the coolant temperature sensor, the engine oil temperature sensor, and the temperature sensor upstream of the exhaust gas turbocharger (turbocharger protection).

After evaluating the input signals, the CDI control unit regulates the fuel pressure in the rails via the quantity control valve and the pressure regulating valve, and controls the injection period by actuating the fuel injectors.

IMPORTANT If the engine oil or coolant temperature is too high, a warning message in instrument cluster is shown. To do this, the CDI control unit sends an appropriate signal via the drive CAN, powertrain control unit, suspension FlexRay, electronic ignition lock (EZS) control unit, and the user interface CAN (CAN HMI) to the instrument cluster.

Electrical function schematic for heat management PE07.10-D-2712-97TSA
Overview of system components for common rail diesel injection (CDI) GF07.16-D-9997TSA