LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2019 >> Sprinter 3500XD Van Cargo Extended, 4WD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control >> Testing & Repair >> Remove/Install Overheating/Flame Temperature Sensor - Ar83.70-D-5745TSR
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Remove/Install Overheating/Flame Temperature Sensor - Ar83.70-D-5745TSR

Model 907.6/7 

with code H11 (Auxiliary hot-air heater) 

G13791862
  Information on preventing damage to electronic components due to electrostatic discharge   AH54.00-P-0001-01A
REMOVINGINSTALLING Remove/install     
1 Remove heater from housing.   AR83.70-D-5399TSR 
2 Release and disconnect electrical connector (2).    
3 Release locking clamp (3) at heat exchanger (4) and remove heat exchanger (4).    
4 Expose electrical wiring harness of overheating/flame temperature sensor (1) at heat exchanger (4) and remove overheating/flame temperature sensor (1). INSTALLATION NOTESInstallation: 
Ensure that overheating/flame temperature sensor (1) lies flat against heat exchanger (4). Otherwise, the heater will malfunction, INSTALLATION IMPORTANT : Ensure that electrical wiring harness of overheating/flame temperature sensor (1) at heat exchanger (4) is routed correctly.
 
5 Install in the reverse order.