Bench Testing
NOTE:
During short circuit test, minimum input voltage to starter is 8 volts on gasoline engine starter motors. Minimum input voltage for diesel engine starter motor is 7.8 volts.
SHORT CIRCUIT TEST (1)
| Application | Volts | Amps | ||
|---|---|---|---|---|
| 6-Cylinder (Gas) | 3.8 | 650-840 | ||
| 6-Cylinder (Diesel) | 2.2 | 520-690 | ||
|
||||
IDLE SPEED TEST
| Application | (1) Amps | Minimum RPM | ||
|---|---|---|---|---|
| Gas (@ 11.5 Volts) | 95 | 2800 | ||
| Diesel (@ 10.5 Volts) | 160 | 4200 | ||
|
||||