LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 1993 >> 300E (124.032) L6-3.2L (104.992) >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Technical Service Bulletins >> All Technical Service Bulletins >> Impulse Readout of LH-SFI Control Module
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Impulse Readout of LH-SFI Control Module

07.4-91101 Impulse Readout (malfunction memory) of Engines 104, 119, 120 Revised 7/92 - 10/91
LH-SFI Control Module with LH-SFI

If the LH-SFI fuel injection malfunction memory has impulse readout 4 or 10, perform the following procedures.

1) On/off ratio readout with ignition ON.

2) On/off ratio readout with engine at idle

3) If the on/off ratio readout is fixed at 50 % with ignition ON, and oscillates with engine at operating temperature and idling, the malfunction memory is in error.

Remedy:

1,2) If On/off ratio readout is fixed at a value other than 50 % with ignition ON, and/or does not oscillate with engine at operating temperature and idling, perform diagnostics.

3) Replace LH-SFI control module with version listed in parts information table below.

Parts Information:





LH-SFI Control Module





LH Malfunction Memory