July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!
DTC P0335:00: Notes
DTC P0335:00
CKP sensor circuit problem
DETECTION CONDITION
If the PCM does not receive the input voltage from the CKP sensor for 4.2 s
while the MAF is 1.95 g/s {0.25 lb/min} or above
, the PCM determines that the CKP sensor circuit has a malfunction.
Diagnostic support note
This is a continuous monitor (CCM).
The MIL illuminates if the PCM detects the above malfunction condition during first drive cycle.
FREEZE FRAME DATA (Mode 2)/Snapshot data is available.
The DTC is stored in the PCM memory.
POSSIBLE CAUSE
CKP sensor connector or terminal malfunction
Short to ground in wiring harness between CKP sensor terminal C and PCM terminal 2AQ
Short to ground in wiring harness between CKP sensor terminal B and PCM terminal 2W
PCM connector or terminal malfunction
Short circuit in CKP sensor circuits each other
Short to power supply in wiring harness between CKP sensor terminal B and PCM terminal 2W
Open circuit in wiring harness between CKP sensor terminal C and PCM terminal 2AQ
Open circuit in wiring harness between CKP sensor terminal B and PCM terminal 2W
Open circuit in wiring harness between CKP sensor terminal A and body ground