DTC P0830:23 [Advanced Keyless Entry And Push Button Start System]: Notes
DTC P0830:23 (ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM) DETECTION CONDITION AND POSSIBLE CAUSE
| DESCRIPTION |
Short to ground in CPP switch circuit |
| DETECTION CONDITION |
- Keyless control module detects CPP switch ON signal and starter interlock switch off signal for 10 min or more
.
|
| POSSIBLE CAUSE |
- CPP switch connector or terminals malfunction
- CPP switch malfunction
- Keyless control module connector or terminals malfunction
- Short to ground in the wiring harness between the following terminals:
- CPP switch terminal A-Keyless control module terminal 4V
- Keyless control module malfunction
|