No.2 Additional Key Registration Procedure (Using the M-MDS) Conditions: Procedure
- Have one key (key 1) ready for registration.
- Using key 1, turn the ignition switch to the ON position.
NOTE:
- Although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
- Connect the M-MDS to the DLC-2.
- Select "Body/Security/PATS function" from the M-MDS screen menu.
- Perform security access as indicated on the M-MDS screen. (See
NO.6 SECURITY ACCESS PROCEDURE .)
- Select "Program Additional Ignition Key" from the M-MDS screen menu.