Panel Light Control Switch Inspection: Notes
- Remove the panel light control switch without disconnecting the connector. (See PANEL LIGHT CONTROL SWITCH REMOVAL/INSTALLATION .)
- Measure the voltage at the panel light control switch terminals as indicated below.
- Disconnect the panel light control switch connector and inspect for continuity at terminal G.
- If not as specified, inspect the parts listed under "Action."
- If the parts and wiring harnesses are okay but the system still does not work properly, replace the panel light control switch.