LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 1998 >> 626 DX L4-2.0L DOHC >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Oxygen Sensor >> Testing and Inspection >> Oxygen Sensor Monitoring Access Procedure
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Oxygen Sensor Monitoring Access Procedure




NOTE: The Oxygen Sensor Monitoring Test Results allows access to on-board oxygen sensor fault limits and actual values during OBD II drive mode.

1. Perform the "New Generation Star (NGS) tester hook-up procedure."
2. Select VEHICLE AND ENGINE SELECTION.
3. Select NEW VEHICLE YEAR & MODEL. Select year, engine, model with appropriate qualifier, if needed.
4. Turn key on.
5. Move cursor to GENERIC OBD II FUNCTIONS.
Press trigger to enter this selection.
6. Select OXYGEN SENSOR TESTS. Press trigger.
7. Select MANUFACTURING SPECIFIC TEST ID.
Press trigger.
8. Scroll up to the test number (41H) and press trigger.