System Test: PS-1
- Indicates failure of solenoid valve or wiring harness (control unit to solenoid valve). To test, turn ignition off. Disconnect control unit connector. Connect ohmmeter between terminals "M" (Blue/Green wire) and "N" (Blue/Black wire) of control unit connector. See Fig 1 .
- If resistance does not measure 3.5-7.0 ohms, go to next step. If resistance measures 3.5-7.0 ohms, check for poor connections at control unit connector, solenoid valve connector and joint connectors. Recheck resistance. If resistance does not measure 3.5-7.0 ohms, replace control unit. If resistance measures as specified, system is okay.
- Check solenoid valve. See SOLENOID VALVE TEST. If solenoid valve is okay, repair wiring harness between control unit and solenoid valve. If solenoid valve is not okay, replace solenoid valve.