Isolating Compressor
- Connect manifold gauge set to service valves on compressor. Close both gauge valves. Open both service valves to the mid-position.
- Start engine and operate air conditioning. Turn suction service valve slowly clockwise toward front-seated position. When suction pressure is reduced to zero or less, stop engine and quickly close suction service valve (front-seated).
- Front-seat the discharge valve. Loosen oil check plug