LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2008 >> LX 570 >> Repair and Diagnosis >> Engine Performance >> Mode 6 - LEXUS >> RX 400H
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

RX 400H

HEATED OXYGEN SENSOR HEATER

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$42 $90 Multiply by 0.001 (A) Maximum sensor heater current Minimum test limit Maximum test limit
THERMOSTAT

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$E1 $E8 Multiply by 01 [°C] ECT sensor output when estimated ECT reached to malfunction criteria Malfunction criteria Maximum test limit
HO2S BANK 1 SENSOR 2

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$02 $07 Multiply by 0.001 (V) Minimum sensor voltage Minimum test limit Maximum test limit
$02 $08 Multiply by 0.001 (V) Maximum sensor voltage Minimum test limit Maximum test limit
$02 $8F Multiply by 0.001 (V) Maximum oxygen storage capacity 0 Maximum test limit
HO2S BANK 2 SENSOR 2

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$06 $07 Multiply by 0.001 (V) Minimum sensor voltage Minimum test limit Maximum test limit
$06 $08 Multiply by 0.001 (V) Maximum sensor voltage Minimum test limit Maximum test limit
$06 $8F Multiply by 0.001 (V) Maximum oxygen storage capacity 0 Maximum test limit
MISFIRE MONITOR - ALL CYLINDERS

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A1 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65535
$A1 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65535
MISFIRE MONITOR - CYLINDER 1

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A2 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65535
$A2 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65535
MISFIRE MONITOR - CYLINDER 2

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A3 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65535
$A3 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65535
MISFIRE MONITOR - CYLINDER 3

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A4 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65535
$A4 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65535
MISFIRE MONITOR - CYLINDER 4

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A5 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65535
$A5 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 6,535
MISFIRE MONITOR - CYLINDER 5

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A6 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65535
$A6 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65535
MISFIRE MONITOR - CYLINDER 6

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$A7 $0B Multiply by 1 [time] Exponential weighted moving average misfire counts for last 10 driving cycles - total 0 65535
$A7 $0C Multiply by 1 [time] Misfire counts for last and current driving cycles - total 0 65535
TID $01: CATALYST - USING A/F SENSOR AND HO2

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.0078 (no dimension) Catalyst deterioration level (bank 1):
Determined by waveform of A/F sensor and HO2S
Malfunction criterion
0 $01 Multiply by 0.0078 (no dimension) Catalyst deterioration level (bank 1):
Determined by waveform of A/F sensor and HO2S
Malfunction criterion for catalyst deterioration

Bank 1 Sensor 1 

A/F SENSOR BANK 1 SENSOR 1

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$01 $91 Multiply by 0.003 [mA] Air-fuel ratio sensor current for bank 1 sensor 1 Malfunction criterion for low side rationality Malfunction criterion for high side rationality
A/F SENSOR BANK 2 SENSOR 1

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$05 $91 Multiply by 0.003906 [mA] A/F current Minimum Test Limit Maximum Test Limit
TID $06: A/F SENSOR

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.000244 (No dimension) Parameter for identify A/F sensor response rate (bank 1) Malfunction criterion
0 $11 Multiply by 0.000244 (No dimension) Parameter for identify A/F sensor response rate (bank 2) Malfunction threshold for A/F sensor deterioration
EVAP

MID TID Scaling Description
$3D $CB Multiply by 0.001 {kPa} Test value for vacuum pump OFF stuck (P2401)
$CD Multiply by 0.001 {kPa} Test value for vacuum pump ON stuck (P2402)
$CE Multiply by 0.001 {kPa} Test value for vent valve OFF stuck (P2420)
$CF Multiply by 0.001 {kPa} Test value for vent valve ON stuck (P2419)
$D0 Multiply by 0.001 {kPa} Test value for reference orifice low-flow (P043E)
$D1 Multiply by 0.001 {kPa} Test value for reference orifice high-flow (P043F)
$D4 Multiply by 0.001 {kPa} Test value for purge VSV close stuck (P0441)
$D5 Multiply by 0.001 {kPa} Test value for purge VSV open stuck (P0441)
$D7 Multiply by 0.001 {kPa} Test value for purge flow insufficient (P0441)
$D8 Multiply by 0.001 {kPa} Test value for canister small leak (P1420)
$D9 Multiply by 0.001 {kPa} Test value for canister gross leak (P1421)
$DA Multiply by 0.001 {kPa} Test value for fuel tank small leak (P1422)
$DB Multiply by 0.001 {kPa} Test value for fuel tank gross leak (P1423)
$DC Multiply by 0.001 {kPa} Test value for fuel vapor-containment valve close stuck (P2451)
$DD Multiply by 0.001 {kPa} Test value for fuel vapor-containment valve open stuck (P2450)