Inspection Procedure
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - ELECTRICAL KEY OSCILLATOR)
- Disconnect the E13 ECU connector.
- Disconnect the oscillator connectors.
- Measure the resistance according to the value(s) in the table below.
Standard resistance:
Inside Luggage Compartment
RESISTANCE SPECIFICATION CHARTTester Connection (Symbols) Condition Specified Condition E13-16 (CG7B) - R2-3 (CLGB) Always Below 1 Ω E13-15 (CLG7) - R2-1 (CLG6) Always Below 1 Ω E13-16(CG7B) - Body ground Always 10 kΩ or higher E13-15 (CLG7) - Body ground Always 10 kΩ or higher Outside Luggage Compartment
RESISTANCE SPECIFICATION CHARTTester Connection (Symbols) Condition Specified Condition E13-32 (CG8B) - R3-2 (CLGB) Always Below 1 Ω E13-31 (CLG8) - R3-1 (CLG5) Always Below 1 Ω E13-32(CG8B) - Body ground Always 10 kΩ or higher E13-31 (CLG8) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK AND REPLACE ELECTRICAL KEY OSCILLATOR
- Replace the electrical key oscillator.
- Check that the luggage compartment door entry LOCK/UNLOCK function operates normally.
OK:
Luggage compartment door entry LOCK/UNLOCK function operates normally.
OK: END (ELECTRICAL KEY OSCILLATOR IS DEFECTIVE)
NG: Go to next step
- PERFORM ACTIVE TEST BY TECHSTREAM (CERTIFICATION ECU OUTPUT SIGNAL)
- Reconnect the oscillator and the ECU connectors.
- Connect Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the tester on.
- Enter the following menus: Body Electrical / Smart Access / Active Test.
- Perform the Active Test according to the display on the tester.
Smart Access:
SMART ACCESS ACTIVE TEST REFERENCETester Display Test Part Control Range In-Bdr Transmitter Luggage compartment door inner oscillator ON/OFF Bdoor Transmitter Luggage compartment door outer oscillator ON/OFF - Measure the frequency according to the value(s) in the table below.
Standard:
Inside Luggage Compartment
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection (Symbols) Condition Specified Condition E13-16 (CG7B) - E13-15 (CLG7) During Active Test Frequency is generated (higher than 0 Hz) Outside Luggage Compartment
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection (Symbols) Condition Specified Condition E13-32 (CG8B) - E13-31 (CLG8) During Active Test Frequency is generated (higher than 0 Hz)
NG: REPLACE CERTIFICATION ECU
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE