Inspection Procedure
HINT:
The AFS OFF switch uses the multiplex communication system. First make sure that the multiplex communication system is functioning normally before performing troubleshooting on the AFS OFF switch.
- READ VALUE OF INTELLIGENT TESTER (AFS OFF SWITCH)
- Connect the intelligent tester to (with CAN VIM) the DLC3.
- Turn the power switch ON (IG) and turn the intelligent tester main switch ON.
- Select the items below in the DATA LIST, and read the displays on the intelligent tester.
Integration control and panel
DATA LISTItem Measurement Item / Display (Range) Normal Condition AFS OFF SW AFS OFF switch / ON or OFF ON: AFS switch ON
OFF: AFS switch OFFOK: The display is as specified in the normal condition.
NG: REPLACE INTEGRATION CONTROL AND PANEL ASSEMBLY
OK: GO TO Next Step
- READ VALUE OF INTELLIGENT TESTER (AFS OFF SWITCH)
- Connect the intelligent tester to the DLC3.
- Turn the power switch ON (IG) and turn the intelligent tester main switch ON.
- Select the items below in the DATA LIST, and read the displays on the intelligent tester.
AFS ECU
DATA LISTItem Measurement Item / Display (Range) Normal Condition AFS OFF SW AFS OFF switch / ON or OFF ON: AFS switch ON
OFF: AFS switch OFFOK: The display is as specified in the normal condition.
NG: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
OK: REPLACE COMBINATION METER ASSEMBLY