On-Vehicle Inspection

  1. CHECK AIR CONDITIONING SOLAR SENSOR 
    1. Disconnect the A/C solar sensor connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Condition Specified Condition
      L1-3 (CLTE) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Condition Specified Condition
      L1-6 (CLTB) - L1-3 (CLTE) Engine switch on (IG) 10 to 14 V
    Fig 1: Identifying Air Conditioning Solar Sensor Connector Terminals
    G05297743Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSPECT SOLAR SENSOR 
    1. Remove the A/C solar sensor with the connector still connected.
    2. Apply battery voltage between terminals 6 (CLTB) and 3 (CLTE) of the A/C solar sensor.
    3. Measure the voltage according to the value(s) in the table below.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Condition Specified Condition
      1 (TSL) - 3 (CLTE) Sensor is subjected to electric light 0.8 to 4.3 V
      1 (TSL) - 3 (CLTE) Sensor is covered by a cloth Below 0.8 V
      Fig 2: Identifying Solar Sensor Connector Terminals
      G05297971Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      NOTE: The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 2 and negative (-) lead to terminal 1 of the solar sensor.

      HINT:

      • As the inspection light is moved away from the sensor, the voltage increases.
      • Use an incandescent lamp for inspection. Bring it about 30 cm (11.8 in.) from the solar sensor.