Abs Motor Relay: Inspection
- INSPECT ABS MOTOR RELAY (ABS MTR1 RELAY, ABS MTR 2 RELAY)
- Measure the resistance according to the value(s) in the table below.
Resistance
TESTER CONNECTION AND SPECIFIED CONDITION
| Tester Connection |
Connection |
Specified Resistance |
| 3 - 5 |
Always |
10 kΩ or higher (No continuity) |
| 3 - 5 |
Apply B+ between terminals 1 and 2 |
Below 1 Ω |