September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Circuit Opening Relay: Inspection
- INSPECT CIRCUIT OPENING RELAY
- Continuity inspection.
- Using an ohmmeter, check for resistance between the terminals.
Resistance
CIRCUIT OPENING RELAY
| Terminals |
Specified Condition |
| 3-5 |
10 kΩ or higher |
| 3-5 |
Below 1 Ω (Apply battery voltage terminals 1 and 2) |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002