Inspection Procedure
WARNING: This page is about a different car, the 2007 Lexus RX 350. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK DTC
- Turn the ignition switch to the ON position, and wait for at least 10 seconds.
- Check for DTCs (See DTC CHECK / CLEAR
).
Result:
A:
DTCs B1771 and B1795 are output.
B:
DTC B1795 is output.
HINT:
Codes other than DTCs B1771 and B1795 may be output at this time, but they are not related to this check.
A: GO TO DTC B1771
B: Go to Next Step
- CHECK FUSE
- Measure the resistance of the ECU-B fuse.
Standard resistance:
Below 1 Ω
NG: REPLACE FUSE
OK: Go to Next Step
- Measure the resistance of the ECU-B fuse.
- CHECK WIRE HARNESS (SOURCE VOLTAGE)
- Turn the ignition switch to the LOCK position.
- Disconnect the negative (-) terminal cable from the battery.
- Disconnect the connector from the occupant classification ECU.
- Connect the negative (-) terminal cable to the battery.
- Turn the ignition switch to the ON position.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
STANDARD VOLTAGE SPECIFICATIONSTester Connection Condition Specified Condition O3-1 (+B) - Body ground Always 10 to 14 V O3-7 (IG) - Body ground Ignition switch ON 10 to 14 V - Turn the ignition switch to the LOCK position.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
STANDARD RESISTANCE SPECIFICATIONSTester Connection Condition Specified Condition O3-3 (GND) - Body ground Always Below 1 Ω
NG: REPAIR OR REPLACE WIRE HARNESS
OK: Go to Next Step
- REPLACE OCCUPANT CLASSIFICATION ECU
- Turn the ignition switch to the LOCK position.
- Disconnect the negative (-) terminal cable from the battery.
- Replace the occupant classification ECU (See REMOVAL
).
HINT:
Perform the inspection using parts from a normal vehicle if possible.
- PERFORM ZERO POINT CALIBRATION
- Connect the negative (-) terminal cable to the battery.
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch to the ON position.
- Using the intelligent tester, perform "zero point calibration" (See INITIALIZATION
).
OK:
"COMPLETED" is displayed.
- PERFORM SENSITIVITY CHECK
- Using the intelligent tester, perform "sensitivity check" (See INITIALIZATION
).
Standard values:
27 to 33 kg (59.52 to 72.75 lb)
NEXT: END