LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 1995 >> ES 300 >> Repair and Diagnosis (Single Page) >> Body & Frame >> Power Windows >> Testing >> One Touch Power Window System/Current Of Circuit >> Using An Ammeter
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Using An Ammeter

  1. Disconnect the connector from the master switch.
  2. Connect the positive (+) lead from the ammeter to terminal 3 on the wire harness side of the connector and the negative (-) lead to negative terminal of the battery. See Fig 1.
  3. Connect the positive (+) lead from the battery to terminal 6 on the wire harness side of the connector. See Fig 1.
  4. As the window goes down, check that the current flow is approximately 7 A. See Fig 2.
  5. NOTE: The circuit breaker opens some 4-40 seconds after the window stops going down, so that a check must be made before the circuit breaker operates.
  6. Check that the current increases up to approximately 14.5 A or more when the window stops going down. If operation is not as specified, replace the master switch.
Fig 1: Testing One Touch Power Window System (1 Of 2)
G00148036Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Fig 2: Testing One Touch Power Window System (2 Of 2)
G00148037Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002