Component Inspection: Notes
- Ignition "OFF".
- Connect KDS/GDS to Data Link Connector (DLC).
- Ignition "ON".
- Perform "Shift Control Solenoid Valve (UD/C)" and "Shift Control Solenoid Valve (OD/LR)" in "Actuation Test" with KDS/GDS.
- Monitor "Shift Control Solenoid Valve (UD/C)" and "Shift Control Solenoid Valve (OD/LR)" in "Current Data" with KDS/GDS.
Specification : Refer to Fig 1 below
- Is displayed parameter within specification?
YES
- Refer to ATM REPAIR PROCEDURES and repair or replace A/T as necessary.
NO
- Carefully re-do this troubleshooting guide steps.
- If problem still occurs, repair or replace Shift Solenoid circuit or Shift Solenoid Valves and then go to "Verification Of REPAIR " procedure.