Bank 2
- Disconnect and isolate the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), disconnect the IBS connector first before disconnecting the negative battery cable.
Courtesy of CHRYSLER GROUP, LLC
|
- Disconnect the right side PCV hose (2) from the supercharger and position aside.
Courtesy of CHRYSLER GROUP, LLC
|
- Clean the area around Temperature and Manifold Absolute Pressure (TMAP) sensor (2).
- Disconnect the TMAP sensor wire harness connector (1).
- Remove screw (3) and the TMAP sensor (2) from supercharger.