September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Default Action
The MIL will illuminate.
The FPCM PWM Control circuit will be reduced to 0% PWM for a calibrated amount of time and then powered to 50%. If the over temperature condition persists, the output will be shut down.