Sensor, Particulate Matter: Installation
Courtesy of CHRYSLER GROUP, LLC
|
- Install the Particulate Matter (PM) sensor (1) and tighten to 60 N.m (44 ft. lbs.).
Courtesy of CHRYSLER GROUP, LLC
|
- Install the PM module (4). Tighten the nuts (2) to 11 N.m (8 ft. lbs.).
- Connect the PM sensor wire harness connector (1).
Courtesy of CHRYSLER GROUP, LLC
|
- Install the module mounting bracket (2). Tighten the nuts (1) to 11 N.m (8 ft. lbs.).
Courtesy of CHRYSLER GROUP, LLC
|
- Install the heat shield (2) and fasteners (1).
Courtesy of CHRYSLER GROUP, LLC
|
- Install the fuel filter shield (1). Tighten the nuts (2) 14 N.m (10 ft. lbs.).
- Remove the support and lower the vehicle.
- Connect the negative battery cables.