September 30: LEMON manuals is back up on a temporary server! Slowness is possible
No Response From Remote Keyless Entry
- Turn ignition switch to OFF position. Disconnect Remote Keyless Entry (RKE) module harness connector, if equipped. See COMPONENT LOCATIONS
. Measure voltage between ground and terminal No. 2 (Pink wire) at RKE module harness connector. See Figure
. If voltage is less than 10 volts, repair open in Pink wire. Perform BODY VERIFICATION TEST
under VERIFICATION TESTS. If voltage is 10 volts or greater, go to next step.
- Ensure all lights are off. Measure resistance between ground and terminals No. 3 and 9 (both Black wires) at RKE module harness connector. If all resistances are less than 5 ohms, go to next step. If any resistance is 5 ohms or greater, repair open in appropriate Black wire. Perform BODY VERIFICATION TEST
under VERIFICATION TESTS.
- Using a jumper wire, ground terminal No. 6 (Violet/Brown wire) at RKE module harness connector. Turn ignition switch to ON position. Using scan tool, enter SYSTEM MONITORS then CCD BUS TEST. If scan tool displays SHORT TO GROUND, go to next step. If scan tool does not display SHORT TO GROUND, repair open in Violet/Brown wire. Perform BODY VERIFICATION TEST
under VERIFICATION TESTS.
- Turn ignition switch to OFF position. Using a jumper wire, ground terminal No. 12 (White/Black wire) at RKE module harness connector. Turn ignition switch to ON position. Using scan tool, enter SYSTEM MONITORS then CCD BUS TEST. If scan tool displays SHORT TO GROUND, replace RKE module. See REMOTE KEYLESS ENTRY MODULE
under REMOVAL & INSTALLATION. Perform BODY VERIFICATION TEST
under VERIFICATION TESTS. If scan tool does not display SHORT TO GROUND, repair open in White/Black wire. Perform BODY VERIFICATION TEST
under VERIFICATION TESTS.