LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Isuzu >> 2003 >> Rodeo 2WD L4-2.2L >> Repair and Diagnosis >> Specifications >> Capacity Specifications >> Heating and Air Conditioning >> System Specifications
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

System Specifications

General Specifications

Heater Unit

Temperature control Reheat air mix system
Capacity 4.3 kw (3700 Kcal./hr.)
Airflow 280 cu.m/h

HEATER CORE

Type Fin and tube type
Element dimension 167 mm (6.6 in.) X 151 mm (5.9 in.) X 35 mm (1.4 in.)
Radiating area Approx. 2.4 sq.m

EVAPORATOR ASSEMBLY

Capacity 4.8 kw (4100 Kcal./hr.)
Airflow 430 cu.m/hr

EVAPORATOR CORE

Type AI-laminate louver fin type
Element dimension 235 mm (9.3 in.) X 224 mm (8.8 in.) X 60 mm (2.4 in.)

EXPANSION VALVE

Type External pressure equalizer type

THERMOSTAT SWITCH

Type Electronic thermostat
OFF: Below 1.0 ± 0.5 °C (33.8 ± 0.9 °F)
ON: Above 2.0 ± 0.3 °C (3.6 ± 0.5 °F)

CONDENSER

Type Parallel flow type

Radiation performance 112.9kw (11,100 Kcal./hr.)

RECEIVER/DRIER

Type Assembly includes sight glass with dual (triple) pressure switch (V6) or pressure sensor (L4)
Internal volume 300 cc (10 fl.oz.)

PRESSURE SWITCH

Dual pressure switch-
Low pressure control
ON: 205.9 ± 29.4 kPa (29.9 ± 4.3 psi)
OFF: 176.5 ± 24.5 kPa (25.6 ± 3.6 psi)

High pressure control

ON: 2353.6 ± 196.1 kPa (341.3 ± 28.4 psi)

OFF: 2942.0 ± 196.1 kPa (426.6 ± 28.4 psi)
Triple pressure switch (V6, A/T)

Low pressure control

ON: 196.3 ± 29.4 kPa (27.0 ± 4.3 psi)

OFF: 176.5 ± 19.6 kPa (25.6 ± 2.8 psi)

Medium pressure control

ON: 1471.0 ± 98.1 kPa (213.3 ± 14.2 psi)
OFF: 1078.7 ± 117.7 kPa (156.4 ± 17.7 psi)

High pressure control

ON: 2353.6 ± 196.1 kPa (341.3 ± 28.4 psi)

OFF: 2942.0 ± 196.1 kPa (426.6 ± 28.4 psi)

REFRIGERANT

Type HFC-134a

Specified amount 700 g (1.54 lbs.)