October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Cycling Switch
MEDIUM PRESSURE SWITCH Low and high switch operation is the same as the dual pressure switch. The medium pressure switch will close when system pressure exceeds 1471.5 ± 98.1 kPa (213.3 ± 14.2 psi), turning on the condenser fan.