DTC Diagnosis Procedure
- CHECK HEATED OXYGEN SENSOR 2 HEATER POWER SUPPLY CIRCUIT - 1
- Turn ignition switch OFF.
- Disconnect heated oxygen sensor 2 harness connector.
- Turn ignition switch ON.
- Check the voltage between heated oxygen sensor 2 harness connector and ground.
+
-
Voltage
Heated oxygen sensor 2
Bank
Connector
Terminal
1
F125
1
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 2.
NO
GO TO 4.
- CHECK HEATED OXYGEN SENSOR 2 HEATER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between heated oxygen sensor 2 harness connector and ECM harness connector.
+
-
Continuity
Heated oxygen sensor 2
ECM
Bank
Connector
Terminal
Connector
Terminal
1
F125
2
F143
6
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HEATED OXYGEN SENSOR 2 HEATER
Check heated oxygen sensor 2 heater. Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END.
NO
Replace malfunctioning heated oxygen sensor 2. Refer to CATALYST : Exploded View .
- CHECK HEATED OXYGEN SENSOR 2 HEATER POWER SUPPLY CIRCUIT - 2
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and heated oxygen sensor 2 harness connector.
+
-
Continuity
IPDM E/R
Heated oxygen sensor 2
Connector
Terminal
Connector
Terminal
E123
52
F125
1
Existed
- Also check harness for short to ground.
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.