Physical Values
| Terminal (Wire color) | Description | Condition | Value (Approx.) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | |||||||
| 1 (Y) | Ground | Power supply | Input | Ignition switch ON | Battery voltage | |||||
| Ignition switch OFF | 0 V | |||||||||
| 2 (R) | Ground | Power supply (Memory back-up) | Input | Always | Battery voltage | |||||
| 3 (L) | - | CAN-H | Input/Output | - | - | |||||
| 4 (V) | - | K-line | Input/Output | - | - | |||||
| 5 (B) | Ground | Ground | Output | Always | 0 V | |||||
| 6 (G) | Ground | Power supply | Input | Ignition switch ON | Battery voltage | |||||
| Ignition switch OFF | 0 V | |||||||||
| 7 (SB) | Ground | Back-up lamp relay | Input | Ignition switch ON | Selector lever in "R" position. | 0 V | ||||
| Selector lever in other than above. | Battery voltage | |||||||||
| 8 (P) | - | CAN-L | Input/Output | - | - | |||||
| 9 (LG)(1) (BR)(2) | Ground | Starter relay | Output | Ignition switch ON | Selector lever in "N" and "P" positions. | Battery voltage | ||||
| Selector lever in other than above. | 0 V | |||||||||
| 10 (B) | Ground | Ground | Output | Always | 0 V | |||||
|
||||||||||