Power Supply And Ground
- through 10A fuse [No. 20, located in the fuse block (J/B)]
- to ASCD brake switch terminal 1 and
- to park/neutral position relay terminal 3,
- to ASCD control unit terminal 5
- through 15A fuse [No. 17, located in the fuse block (J/B)]
- to stop lamp switch terminal 1
- through 10A fuse [No. 9, located in the fuse block (J/B)]
- to combination meter terminal 59
Power is supplied at all times:
- through 15A fuse [No. 17, located in the fuse block (J/B)]
- to the stop lamp switch terminal 1, and
- to ASCD control unit terminal 23
When park/neutral position is in the P or N position, ground is supplied:
- to park/neutral position relay terminal 2
- through park/neutral position switch and body grounds E24 and E44.
When ASCD main switch is depressed (ON), ground is supplied:
- to ASCD control unit terminal 11
- from ASCD steering switch terminal 1
- to ASCD steering switch terminal 2
- from ASCD control unit terminal 24.
then ASCD control unit holds CRUISE condition and illuminates CRUISE indicator.
Ground is supplied:
- to combination meter terminal 63
- from ASCD control unit terminal 15.