Charging System

CHARGING SYSTEM SPECIFICATIONS

Items Specification
Alternator Type I.C. regulator built-in
Rate voltage 13.5 V, 90A
Speed in use 1, 000 ~ 18, 000 RPM
Voltage regulator Electronic built-in type
Regulator setting voltage 14.4 ± 0.1 V
Temperature compensation -3.5 ± 2 mV/°C
Battery Type 44-21GL
Cold cranking amperage [at -18 °C (-0.4 °F)] 500 A
Reserve capacity 85 min
Specific gravity [at 20 °C (68 °F)] 1.280 ± 0.01
CAUTION:
  • COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2 V or greater at a specified temperature.
  • RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5 V at 26.7 °C (80.1 °F).
    Fig 1: Identifying Battery Label
    G06879256Courtesy of HYUNDAI MOTOR CO.